Overview
The Komatsu D85EXi-18, D85PXi-18 dozer repair service manual provides a technical reference for the covered equipment. Its purpose is to help locate information relevant to inspection, troubleshooting, servicing and repair, as applicable to the supplied publication.
The supplied contents outline identifies Manuals, Index and foreword, Specification and Structure, function and maintenance standard. The table below follows the provided section names and selected topics; consult the manual for the exact procedures and specifications.
Important Information: Confirm the applicable serial-number or production range in the supplied documentation before selecting a procedure.
Table of Contents
Komatsu D85EXi-18, D85PXi-18 Manual
Main sections and selected subjects identified in the source documentation:
- Manuals: Shop Manual and Operation and Maintenance Manual
- Index and foreword
- Specification
- Structure, function and maintenance standard
- Standard value table
- Testing and adjusting
- Troubleshooting
- Disassembly and assembly
- Maintenance Standard
- Appendix
- Circuit Diagrams
- Index
- | FAILURE CODE [879BKA] A/C Fresh Air Temperature Sensor Open Circuit
- | Details of
- failure
- | Air conditioner controller detects open circuit in outside air temperature sensor.
- | Action of
- controller
- | Air conditioner controller transmits open circuit information of outside air temperature sensor to machine monitor by CAN communication.
- Ignores data of outside air temperature sensor and continues control of air conditioner in automatic air conditioner mode.
- | Phenomenon
- on machine
- (Air conditioner is not affected in manual mode.)
- | Related
- information
- | • After repairing, check if the failure code is cleared by the following procedure.
- Procedure: Turn starting switch to ON position.
- Check if this failure code is displayed on electrical system failure record screen in service
- mode of machine monitor.
- For each connector, see “Installation locations of air conditioner parts and arrangement of
- connectors”.
- Since air conditioner controller connector ACECU has no T-adapter and has small pins,
Serial-Number Applicability
The covered production ranges or serial groups may affect the applicable procedures. Check the identification details on the machine against the source documentation.










Reviews
There are no reviews yet.