| FAILURE CODE [879BKA] A/C Fresh Air Temperature Sensor Open Circuit
| Details of
failure
| Air conditioner controller detects open circuit in outside air temperature sensor.
| Action of
controller
| Air conditioner controller transmits open circuit information of outside air temperature sensor to machine monitor by CAN communication.
Ignores data of outside air temperature sensor and continues control of air conditioner in automatic air conditioner mode.
| Phenomenon
on machine
| Since air conditioner outside air temperature sensor has open circuit, outside air temperature is not considered in automatic air conditioner mode.
(Air conditioner is not affected in manual mode.)
| Related
information
| • After repairing, check if the failure code is cleared by the following procedure.
Procedure: Turn starting switch to ON position.
Check if this failure code is displayed on electrical system failure record screen in service
mode of machine monitor.
For each connector, see “Installation locations of air conditioner parts and arrangement of
connectors”.
Since air conditioner controller connector ACECU has no T-adapter and has small pins,
perform troubleshooting by using intermediate connector (although intermediate connector
has no T-adapter either, it has large pins).
When replacing air conditioner harness between air conditioner controller connector ACECU
and intermediate connector, replace air conditioner unit.
Use publication SEN06576-01 and TEN00712-02 with the D85EXi-18, D85PXi-18 model details to select the appropriate documentation. Refer to Specification within its stated document and equipment scope.