For Komatsu D61EXi-24, D61PXi-24 Dozer, this reference brings together the listed repair manual material. Start with Specification and follow the relevant document section for the task.
What’s Covered Inside
Operation and Maintenance Manual: 441 pages
Serial Number:
40001 and Up (SEN06578-00)
B60001 and up (KEBM657800)
40001 and up (TEN00723-04)
B60001 and up (KEBM657900)
Manuals: Shop Manual and Operation and Maintenance Manual
Index and foreword
Specification
Structure, function and maintenance standard
Standard value table
Testing and adjusting
Troubleshooting
Disassembly and assembly
Maintenance Standard
Appendix
Diagrams and drawings
Proper service and repair are extremely important for safe machine operation. The service and repair techniques recommended by Komatsu and described in this manual are both effective and safe. Some of these techniques require the use of tools specially designed by Komatsu for the specific purpose.
Manual Extract – Loaded Diagnostics Operation To Clear Failure Code
Perform the procedure below to check that the repair is completed. (Make sure that this failure code is cleared after this procedure.)
1. Turn the starting switch from OFF position to ON position.
2. Start the engine and run it at low idle speed for 15 minutes.
If the failure code is cleared, repair work is complete. Otherwise, perform the following: NOTICE
If failure code is not cleared after preceding steps 1 and 2 are performed, following temperature requirements are included in clearing condition. Steps 4 and 5 are required to satisfy temperature requirements.
KDOC outlet temperature 200 °C or above
KDPF outlet temperature 200 °C or above
3. Display KDOC outlet temperature and KDPF outlet temperature with monitoring function.
4. Perform continuously the blade RAISE relief for 15 minutes with fuel control dial at MAX (high idle) position.
5. When the KDOC outlet temperature or KDPF outlet temperature does not exceed 200 °C, perform “Loaded Diagnostics Operation To Clear failure Code” [CA1883].
6. If the failure code is cleared, repair work is complete.
Use publication KEBM657800 and SEN06578-00 with the D61EXi-24, D61PXi-24 model details to select the appropriate documentation. Refer to Specification within its stated document and equipment scope.