The Caterpillar EC25N2, EC25EN2 and EC25LN2 listing provides a 417-page service manual, a 189-page operation and maintenance manual and a 216-page controller manual. The sample distinguishes traction and pump inverter discharge from the checks made before reconnecting the battery.
Document Details
CAT EC25N2, EC25EN2, EC25LN2 Forklift Service Manual: 417 Pages
Operation and Maintenance Manual: 189 Pages
Controller Manual: 216 Pages
Publication 99759-8N200
English
Caterpillar CAT EC25N2, EC25EN2, EC25LN2 Lift Truck Manual
Lift Truck Forklift Model: EC25N2, EC25EN2, EC25LN2
Publication 99759-8N200
English
Format: PDF
CAT EC25N2, EC25EN2, EC25LN2 Forklift Service Manual: 417 Pages
Operation and Maintenance Manual: 189 Pages
Controller Manual: 216 Pages
Source Heading
Forklift Manual Table of Content:
Contents Listed
General Information
Electrical System
Power Train
Motor
Transfer and Differential
Front Axle
Rear Axle
Brake System
Steering System
Hydraulic System
Masts and Forks
Service Data
Options
Procedure Excerpt
Discharge electric charges stored in the inverters by using the following procedure.
(1) Turn OFF the key switch.
(2) Disconnect the battery plug/connector.
(3) Remove the rear cover.
(4) Place a 150 Ω/25 W resistor between P and N terminals in the traction inverter to discharge electric charges stored in the inverter.
(5) After touching the resistor to the P and N terminals for approx. five seconds, measure the voltage between the terminals with a multimeter and confirm a reading of 5V or less.
(6) Perform the same procedure for the pump inverter in order to discharge electric charges from all inverters.
Check whether the resistance between + and – of the battery plug/connector on the lift truck side is 1 kΩ or more when connecting the battery plug/connector for the first time after maintenance.
Note: Discharge electric charges completely before measuring. Longer measurement time reduces resistance value.