For Case 335, 385, 435, 485, 535 Steiger Tractor, this reference brings together the listed repair manual material. Start with General and follow the relevant document section for the task.
What’s Covered Inside
General
Engine
Electrical
Steering
Power Train
Brakes
Hydraulics
Chassis
Controllers
Electrical Schematic
Hydraulic Schematic
Manual Extract: Hydraulic controls
All these remote hydraulic controls are hard wired directly into the armrest controller. Each remote control lever actuates a potentiometer within the armrest control console. As a remote control lever is actuated the armrest controller reads the potentiometer setting and sends a signal through the Case Data Bus (CDB) to the remote controller. The remote controller sends the signal onto a proportional solenoid which shifts the main valve spool allowing flow through to the respective remote coupler.
The remote controller will report any problems directly to the instrument controller. The instrument controller will display any system faults or fault code information through the standard instrumentation display.
When a fault occurs, a 3 second continuous audible alarm will sound. The audible alarm will stop after 3 seconds.
Once the fault has been corrected the fault codes should be erased. To erase the fault codes from a controller, press and hold both the INCR and DECR keys for 10 seconds.
Use publication 84257307 – 1 with the 335, 385, 435, 485, 535 Steiger model details to select the appropriate documentation. Refer to General within its stated document and equipment scope.