For Case CX330 Excavator, this reference brings together the listed repair manual material. Start with General and follow the relevant document section for the task.
What’s Covered Inside
Manuals: Service Manual
General
Engines
Fuel System
Electrical
Undercarriage
Drive Train
Hydraulics
Upper structure
Manual Extract
CLEANING THE HYDRAULIC SYSTEM
General remarks
Contamination of the hydraulic system is a major cause of incorrect operation of hydraulic components.
The contamination results from the presence of foreign bodies in the hydraulic fluid. Contamination of the hydraulic system can occur in any of the following situations:
1. When draining the fluid or reconnecting the hydraulic lines.
2. When removing a component.
3. Due to normal component wear.
4. Due to damaged or worn seals.
5. Due to a damaged component in the hydraulic system.
All hydraulic systems can function even if they are slightly contaminated. The components of the hydraulic system are designed to support slight contamination.
Any increase in the degree of contamination can cause serious problems in the hydraulic system.
Here is a non-exhaustive list of these problems:
1. The cylinder rod seals are leaking.
2. Control valve spools do not return to the neutral position.
3. The control valve spools do not move easily.
4. Hydraulic fluid is too hot.
5. Hydraulic components wear quickly.
6. Safety valves or non-return check valves do not close due to contamination.
7. Repaired components break down soon.
8. Cycles are slow; the machine does not have enough power.
If one of the above situation occurs, it shows excessive contamination of the hydraulic system. To eliminate this contamination effectively, use the portable filter CAS 10162A.
General
Engines
Fuel System
Electrical
Undercarriage
Drive Train
Hydraulics
Upper structure
Manual Extract
CLEANING THE HYDRAULIC SYSTEM
General remarks
Contamination of the hydraulic system is a major cause of incorrect operation of hydraulic components.
The contamination results from the presence of foreign bodies in the hydraulic fluid. Contamination of the hydraulic system can occur in any of the following situations:
1. When draining the fluid or reconnecting the hydraulic lines.
2. When removing a component.
3. Due to normal component wear.
4. Due to damaged or worn seals.
5. Due to a damaged component in the hydraulic system.
All hydraulic systems can function even if they are slightly contaminated. The components of the hydraulic system are designed to support slight contamination.
Any increase in the degree of contamination can cause serious problems in the hydraulic system.
Here is a non-exhaustive list of these problems:
1. The cylinder rod seals are leaking.
2. Control valve spools do not return to the neutral position.
3. The control valve spools do not move easily.
4. Hydraulic fluid is too hot.
5. Hydraulic components wear quickly.
6. Safety valves or non-return check valves do not close due to contamination.
7. Repaired components break down soon.
8. Cycles are slow; the machine does not have enough power.
If one of the above situation occurs, it shows excessive contamination of the hydraulic system. To eliminate this contamination effectively, use the portable filter CAS 10162A.
Use publication 9-53592 (June 2002) with the CX330 model details to select the appropriate documentation. Refer to General within its stated document and equipment scope.










Reviews